M27 x 3 Tap Drill Size
Tap drill
24 mm 0.9449 in
Use a 24 mm drill (0.9449 in) for 77.0% thread.
Fine thread M27 x 2? Use 25 mm. (0.9843 in, 77.0% thread)
The drill size for a M27 x 3 tap is 24 mm (0.9449 in). If you are wondering what size drill bit a M27 x 3 tap needs, that is the one: it leaves 77.0% of thread, which is the figure standard tap and drill charts are built around. Below are the other holes you might want for this size - a larger drill for tough material, the form-tap hole, and the clearance holes for the bolt that goes in.
Every drill for M27 x 3
| Use | Drill | Decimal in | mm | % thread |
|---|---|---|---|---|
| Standard tap drill Cut tap, general use (D - P) | 24 mm | 0.9449 | 24.00 | 77.0% |
| Inch substitute Closest inch drill if you have no metric set | 15/16″ | 0.9375 | 23.81 | 81.8% |
| Hard material Stainless, tool steel, anything that fights the tap | 24.5 mm | 0.9646 | 24.50 | 64.2% |
| Form (roll) tap Theoretical 25.67 mm - starting point, check your tap maker's chart | 25.5 mm | 1.0039 | 25.50 | — |
Clearance holes for a M27 x 3 bolt
A clearance hole is not tapped. It is the hole in the part the bolt passes through, so it is always larger than the thread.
| Fit | Hole mm | Hole in |
|---|---|---|
| Fine | 28.00 | 1.1024 |
| Medium | 30.00 | 1.1811 |
| Coarse | 32.00 | 1.2598 |
M27 x 3 dimensions
| Dimension | Inch | mm |
|---|---|---|
| Major diameter | 1.063 | 27.00 |
| Basic internal minor diameter | 0.9351 | 23.75 |
| Pitch | 0.1181 | 3.00 |
| Thread designation | M27 x 3 | |
What the hole looks like
Work out a different hole for M27 x 3
Pre-filled with M27 x 3. Change the material, the tap type, or which drills you actually own, and it picks the closest real drill and tells you the percent of thread you end up with. The tables above are the published figures and do not depend on this.
The general-purpose target
Best drill you have, cut tap, 70% target
61/64″0.9531 in24.21 mm71.6% thread
Theoretical hole 24.27 mm
One size down, deeper thread24 mm 0.9449 in · 77.0%
One size up, easier tapping24.5 mm 0.9646 in · 64.2%
For comparison, the published chart drill for M27 x 3 is 24 mm at 77.0% thread.
Notes on M27 x 3
- Coarse pitch
- M27 x 3 is the coarse pitch at 27 mm. It is the usual choice for general work, and it tolerates a slightly off-size hole better than the finer pitches do. Finer options at the same diameter: M27 x 2, M27 x 1.5.
- What the standard drill gives you
- 24 mm leaves 77.0% of thread (D - P). That is in the normal 65-80% band most shop charts aim for.
- Stainless, tool steel and other tough material
- 24.5 mm opens the hole to 64.2% engagement. Less material for the tap to cut means less torque and less heat, at the cost of some thread depth.
- Using a form (roll) tap
- A form tap displaces metal instead of cutting it, so it needs a larger hole: 25.5 mm, against a theoretical 25.67 mm. Treat that as a starting point and check your tap maker's chart.
- Closest inch size
- 1-1/8-7 is the nearest inch thread by diameter (28.58 mm against 27 mm). It is a planning reference only. The two are not interchangeable: the pitches differ, and a bolt from one will not run into a hole tapped for the other.
Related sizes
Same diameter, different pitch
Next size up and down
Closest inch size
1-1/8-7 63/64″ · 0.9844 in · 25.00 mm · 75.8% 28.58 mm major against 27 mmNot interchangeable. 1-1/8-7 is the nearest size by diameter, nothing more. The pitches differ, so a 1-1/8-7 fastener will not run into a M27 x 3 hole and forcing one will strip both.
Guides for tapping M27 x 3
Longer reads on the decisions behind the numbers above.
- Metric vs Imperial Threads: How to Read and Tell Them Apart Read M8 x 1.25 and 5/16-18 callouts, see why M6 and 1/4-20 are not interchangeable, and identify an unknown thread with a pitch gauge and calipers. Published
- Tap Drill Formula Explained, With Worked Examples How to calculate tap drill size for inch, metric and form taps, check percent of thread, and pick the nearest real drill. Worked 1/4-20 and M8 examples. Published
- Percent of Thread Explained: Why Tap Drill Charts Use 75% What percent of thread means, why charts target about 75%, how strength and tapping torque trade off, and how to pick a drill for your material. Published
M27 x 3 tap drill: common questions
What size drill bit do I need for a M27 x 3 tap?
What is the drill size for a M27 x 3 tap in inches?
What drill should I use for M27 x 3 in stainless steel?
Is M27 x 3 the same as M27 x 2?
What is the clearance hole for an M27 x 3 bolt?
M27 x 3
Metric coarse · 3 mm pitch
| Tap drill | 24 mm | 0.9449 in / 77.0% thread |
|---|---|---|
| Inch substitute | 15/16″ | 0.9375 in / 23.81 mm / 81.8% |
| Hard material | 24.5 mm | 0.9646 in / 64.2% |
| Form tap | 25.5 mm | 1.0039 in |
Clearance hole (ISO 273)
| Fine | 28 mm | 1.1024 in |
|---|---|---|
| Medium | 30 mm | 1.1811 in |
| Coarse | 32 mm | 1.2598 in |
Fine thread M27 x 2: 25 mm ( 0.9843 in)
Major 1.063 in / 27 mm · minor 0.9351 in
tapdrillsizechart.com